Auris Nasus Larynx
Volume 30, Supplement , Pages 145-147, 15 February 2003

Penetrating neck injuries involving wooden foreign bodies: the role of MRI and the misinterpretation of CT images

  • Hideki Imokawa

      Affiliations

    • Department of Otolaryngology St. Marianna University School of Medicine, 2-16-1 Sugao Miyamae-ku, Kawasaki 216-8511, Japan
    • Imokawa Ear, Nose, Throat Clinic, 2-16-1 Komachi, Kamakura-Si, Kanagawa, Japan
    • Corresponding Author InformationCorresponding author. Tel.: +81-44-977-8111; fax: +81-44-976-8748
  • ,
  • Takasi Tazawa

      Affiliations

    • Tazawa Ear, Nose, TroatClimic, 723-1.Kamiyama cyou, Aoba-ku, Yokohama Japan
  • ,
  • Natuki Sugiura

      Affiliations

    • Department of Otolaryngology St. Marianna University School of Medicine, 2-16-1 Sugao Miyamae-ku, Kawasaki 216-8511, Japan
  • ,
  • Daisuke Oyake

      Affiliations

    • Department of Otolaryngology St. Marianna University School of Medicine, 2-16-1 Sugao Miyamae-ku, Kawasaki 216-8511, Japan
  • ,
  • Kiyomi Yosino

      Affiliations

    • Department of Otolaryngology St. Marianna University School of Medicine, 2-16-1 Sugao Miyamae-ku, Kawasaki 216-8511, Japan

Abstract 

A 12-year-old, boy fell in the bush and suffered a penetrating neck wound. Computed tomography(CT-scan) was performed, but no foreign body was detected inside the wound. The patient returned home after ordinary wound care. About 6 months after the accident, the patient visited hospital, because of inflammatory neck pain. A CT-scan was performed and the foreign body appeared as a high density. Magnetic resonance imaging (MRI) revealed the presence of a large foreign body. Under general anesthesia the wooden (bamboo) foreign body was removed. This case highlights the needs to be aware of the potential for misinterpretation of CT images, especially in acute wooden penetration injury. Its also demonstrates that MRI is a useful adjust to CT in the detection of non-metallic foreign bodies.

Keywords:  Accidental penetrating neck injury, Wooden foreign bodies, CT-scan, MRI

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0385-8146(02)00130-X

Auris Nasus Larynx
Volume 30, Supplement , Pages 145-147, 15 February 2003